Enter the wall’s length and height and the AAC block size to get the number of blocks, with wastage added.
How it is calculated
Wall area = length × height, less openings. One block’s face area = block length × block height. Blocks = wall area ÷ block face area, then wastage is added and the result is rounded up. This assumes the wall is one block thick.
Worked example
A 10 m × 3 m wall is 30 m². A 600 × 200 mm block has a face of 0.12 m², so 30 ÷ 0.12 = 250 blocks. With 5% wastage that is 263 blocks.
FAQs
Why does the block width not affect the count? Because the block width sets the wall thickness, which is fixed by design. The count depends on the face area.
Do I need to deduct door and window openings? Yes. Enter their total area in the openings field.